Job:
MVB™ - Type H
Heating/Hot Water Supply Boilers
Models H7 504-2004
Engineer:
Contractor:
Prepared By:
Model:
Date:
Indoor/Outdoor:
84% Thermal Efficiency at Full Rate
100% Factory Fire Tested
Maximum Outlet Water Temperature: 220°F
Minimum Acceptable Inlet Water Temperature: 120°F
Full Safety Diagnostics with History
Footprint: Less Than 5-1/2 ft2
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Heat Exchanger Warranty
Electronic Modulation, Constant Ratio 1.4:1 Turndown
TempTracker Mod Controller with LCD Display
Status Display Lights
Heat Exchanger
Burner
Temperature Controllers
ƒ Bronze Headers
ƒ ASME H Stamped
160 PSIG Working Pressure
ƒ National Board Approved
ƒ Fin Tubing
ƒ Ultra-Low NOx: Less than 20 PPM
B-36 Temp-Tracker Mod+ Digital
Controller, Up to 4 Boilers,
OA Reset
B-37 Temp-Tracker Mod+ Digital
Controller, Up to 10 Boilers,
OA Reset
B-38 Temp-Tracker Mod+ Digital
Controller, Up to 16 Boilers,
OA Reset
Y-241 Electronic Sequencer,
Up to 4 Boilers
Gas Train
ƒ Fuel
Natural Gas
Propane
ƒ Zero Governor Regulator
ƒ Dual-Seat Combination Valve
ƒ Electronic Modulating Firing Mode
Copper – Standard
Cupro Nickel – Option A-3
ƒ ASME Powder-Coated Tube Sheet
ƒ Silicone High Temp O-Rings
ƒ ASME Pressure Relief Valve
60 PSIG – Standard
PSIG – Optional
ƒ Temperature and Pressure Gauge,
Shipped Loose
Construction
ƒ Indoor/Outdoor Construction
ƒ Front Controls Enclosed
ƒ PolyTuf Powder Coat Finish
ƒ Rear Connections (Water, Electrical,
Gas, Vent, Combustion Air)
ƒ Design Certified ANSI Z21.13/
CSA 4.9
Y-281 Electronic Sequencer,
Up to 8 Boilers
Options
ƒ Stainless Steel Evaporator Plate
A-13 Air Vent, Auto, 150 PSI
F-10 Low Water Cut-Off, Remote Probe
Control
ƒ 120V, 60Hz, 1Ø, Power Supply
ƒ 120/24V 60Hz Transformer
ƒ Ignition Module
I-1
I-2
P-
High Limit, Auto Reset, Adj.,
100-240°F
High Limit, Manual Reset, Adj.,
100-240°F
Venting
ƒ Vent Termination Cap
Outdoor - Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)
ƒ Combustion Air
In-Line Filter Kit – Option D-17
Air Intake Elbow – Option D-16
ƒ Extractor – Optional
By others
3-Try – Standard
Single-Try – Option C-6
ƒ Hot Surface Ignition (HSI)
ƒ Remote Flame Sensor
ƒ High Limit, Manual Reset, Fixed,
240ºF
ƒ On/Off Power Switch
ƒ Flow Switch
ƒ Blocked Vent Pressure Switch
ƒ Combustion Air Proving Switch
ƒ Pump Switch
Pump:
HP, 120V, 1∅, 60Hz
Water Hardness:
Cast Iron
GPG
Bronze
Mounted
Loose
P-
P-
Cold Water Start
Cold Water Run
S-1
Low Gas Pressure Switch,
Manual Reset
Not required
S-2
High Gas Pressure Switch,
Manual Reset
ƒ Pump Time Delay
ƒ Diagnostics Panel
Regulatory Agency Requirements
ƒ Modulating Temperature Control
ƒ Water Temperature Sensors (3)
Catalog No.: 2000.364A
Effective: 8-15-07
Replaces: 6-15-07
|
RCA CC9360 User Manual
Pyramid Car Audio Car Amplifier PB1617X User Manual
Panasonic NV GS35GN User Manual
Panasonic Lumix DMC FX10 User Manual
Oster Blender 165734 User Manual
Orion 5271 User Manual
LG Electronics LG Lifes Good Car Video System M2762D User Manual
Kenwood KRC 378R User Manual
JVC Premium and Slim Compact Design Full High Definition Memory Camcorder GZ VX700 User Manual
JVC LYT0189 002A User Manual